Key Considerations
The following key considerations are essential for the safety and performance of medical devices:
General Requirements
- Devices must be designed and manufactured in a way that ensures they are safe and perform as intended.
- They must not compromise the clinical condition or safety of patients.
Design and Manufacturing
- Devices should be designed and manufactured according to safety principles, taking into account the state of the art.
- They should be made from materials that ensure compatibility with biological tissues, cells, and body fluids.
Risk Management
- Implement a comprehensive risk management process throughout the device's lifecycle.
- Identify potential hazards associated with the device and mitigate risks to acceptable levels.
Clinical Evaluation
- Conduct clinical evaluations and investigations to demonstrate that the device performs as intended and is safe.
- Collect and analyze clinical data throughout the device's lifecycle.
Labeling and Instructions for Use
- Provide clear, understandable, and comprehensive labeling and instructions for the safe use of the device.
- Include information on the intended purpose, contraindications, precautions, and any residual risks.
The Essential Principles
4.0 Safety and Performance of Medical Devices – General Essential Principles
Description and Intent
The General Essential Principles focus on ensuring that all medical devices are designed and manufactured to be safe and perform as intended. The principles emphasize the need for devices to achieve their intended purpose without compromising the health and safety of patients, users, or others. They also stress the importance of risk management, ensuring that any risks associated with the device are acceptable when weighed against the benefits to the patient. This involves identifying potential hazards, estimating and evaluating associated risks, and controlling these risks through design and manufacturing processes.
5.0 Essential Principles Applicable to all Medical Devices and IVD Medical Devices
Description and Intent
These principles are applicable to both medical devices and in vitro diagnostic (IVD) medical devices. They include requirements related to:
- Design and Manufacturing: Devices should be designed and manufactured in accordance with safety principles, taking into account the latest technological advancements. This ensures that devices are state-of-the-art and incorporate the latest safety features.
- Risk Management: A thorough risk management process must be implemented throughout the device lifecycle to identify and mitigate potential hazards. This involves continuous assessment and control of risks from the design phase through post-market activities.
- Clinical Evaluation: Clinical data must be collected and analyzed to ensure the device's performance and safety. This step verifies that the device achieves its intended purpose and that any potential risks are outweighed by its benefits.
- Labeling and Instructions for Use: Clear and comprehensive information must be provided to ensure the safe and effective use of the device. This includes accurate and detailed instructions for use, which help prevent misuse and associated risks.
6.0 Essential Principles Applicable to Medical Devices other than IVD Medical Devices
Description and Intent
This section focuses on principles specific to medical devices that are not IVDs. It includes requirements such as:
- Chemical, Physical, and Biological Properties: Ensuring that the materials used are compatible with the biological tissues they will contact. This minimizes the risk of adverse reactions.
- Infection and Microbial Contamination: Measures to minimize infection risks, including sterility requirements. This is crucial for devices that come into contact with the human body.
- Devices with a Measuring Function: Requirements to ensure accuracy and reliability of measurements taken by the device. This is essential for diagnostic devices and those that provide critical data.
- Protection against Radiation: Ensuring that devices emitting radiation are designed to minimize exposure and ensure safety. This protects both patients and healthcare providers from harmful radiation effects.
Methodologies to Fill the Checklist for Compliance
General Approach:
Review Relevant Standards and Guidance Documents:
- Identify and understand the specific standards and guidance documents relevant to each essential principle. Refer to Appendix B for specific guidances and standards like ISO 13485, ISO 14971, GHTF documents, etc.
Conduct a Gap Analysis:
- Compare your current processes, documents, and systems against the requirements of each essential principle.
- Identify gaps where your organization does not meet the specified requirements.
Document Evidence:
- Collect and document evidence that demonstrates compliance with each essential principle. This can include test reports, risk management files, clinical evaluation reports, and quality management system (QMS) records.
Implement Corrective Actions:
- For any identified gaps, develop and implement corrective actions to address the deficiencies.
- Document these actions and their outcomes to provide evidence of compliance.
Specific Methodologies for Each Essential Principle:
Essential Principle 5.1: General Requirements
QMS Implementation:
- Ensure a compliant QMS is in place as per ISO 13485.
- Document all processes, procedures, and controls related to the design, production, and post-market activities.
Corrective and Preventive Actions (CAPA):
- Follow the guidance in GHTF/SG3/N18:2010 to establish CAPA processes.
- Maintain records of CAPA activities, including nonconformance reports, investigations, and resolutions.
Supplier Control:
- Implement supplier control processes as per GHTF/SG3/N17:2008.
- Keep records of supplier evaluations, audits, and performance monitoring.
Process Validation:
- Validate key processes as described in GHTF/SG3/N99-10:2004.
- Document validation protocols, results, and any re-validation activities.
Essential Principle 5.2: Clinical Evaluation
Clinical Evidence:
- Gather clinical data to support the safety and performance of the device.
- Use the guidance from GHTF/SG5/N1R8:2007 and GHTF/SG5/N2R8:2007 to document clinical evaluation activities.
Clinical Investigations:
- Conduct clinical investigations if necessary, as per GHTF/SG5/N3:2010.
- Maintain records of study protocols, ethics committee approvals, and investigation results.
Scientific Validity for IVDs:
- For IVDs, determine scientific validity and performance as per GHTF/SG5/N6:2012 and GHTF/SG5/N7:2012.
- Document evidence of analytical and clinical performance studies.
Essential Principle 5.3: Risk Management
Risk Management Process:
- Implement a risk management process in line with ISO 14971.
- Document risk management plans, risk analyses, risk evaluations, and risk control measures.
Risk Files:
- Maintain risk management files containing all risk-related documentation.
- Include post-market surveillance data to continuously monitor and update risk assessments.
Essential Principle 6.0: Specific to Medical Devices
Chemical, Physical, and Biological Properties:
- Ensure materials are biocompatible and safe for intended use.
- Document material specifications, biocompatibility test results, and compatibility studies.
Infection and Microbial Contamination:
- Implement sterilization and disinfection processes.
- Maintain records of sterilization validation, microbial testing, and packaging integrity tests.
Devices with Measuring Functions:
- Validate measurement accuracy and reliability.
- Document calibration procedures, test results, and performance verification.
Checklist Completion:
Fill the Checklist:
- For each essential principle, fill the checklist with the evidence collected and documented.
- Provide references to specific documents, reports, and records that demonstrate compliance.
Review and Approval:
- Have the checklist reviewed and approved by relevant stakeholders, including regulatory, quality, and clinical teams.
- Ensure any discrepancies or missing information is addressed promptly.
- Keep the completed checklist and all supporting documents organized and readily accessible.
- Use these records for internal audits, regulatory submissions, and inspections.
Essential Principle | Description | Guidance | Documents/Standards |
---|---|---|---|
General Requirements | Devices must be designed and manufactured to ensure safety and performance. | Implement risk management processes. | ISO 14971 |
Chemical, Physical, and Biological Properties | Ensure materials are compatible with biological tissues. | Conduct biocompatibility testing. | ISO 10993 |
Infection and Microbial Contamination | Minimize infection risks; ensure sterility. | Validate sterilization processes. | ISO 11135, ISO 11137 |
Manufacturing and Environmental Properties | Devices must function under specified environmental conditions. | Perform environmental testing. | ISO 13485 |
Devices with Measuring Functions | Ensure accuracy and reliability of measurements. | Calibrate and validate measuring devices. | ISO 8655 |
Protection against Radiation | Design to minimize radiation exposure. | Implement radiation safety measures. | IEC 60601-2-28 |
Labeling and Instructions for Use | Provide clear instructions and labeling. | Develop comprehensive user manuals. | ISO 15223-1 |
Performance and Safety | Devices should perform as intended without compromising safety. | Conduct clinical evaluations. | ISO 14155 |
Clinical Evaluation and Investigations | Validate performance through clinical data. | Perform clinical trials. | ISO 14155 |
Risk Management | Identify and mitigate risks throughout the device lifecycle. | Maintain a risk management file. | ISO 14971 |
Usability | Ensure devices are user-friendly and reduce user errors. | Conduct usability testing. | IEC 62366 |